Room BTU & AC Sizer

Calculate cooling load and recommend target AC sizing

Room Specs

Room Length15 ft
Room Width12 ft
Ceiling Height8 ft
Sun Exposure
Room Occupants2 People
Located in Kitchen?Adds 4,000 BTU load

Required Cooling Capacity

3,600 BTU/h

Calculated heat capacity needed for the space.

Recommended Unit Size

0.75 Ton (9,000 BTU)

Nearest standard commercial capacity size.

Exact Tonnage Load

0.30 Tons

Based exactly on 3,600 BTU/hr cooling load.

Calculated Room Area

180 sq. ft.

Equivalent to 16.7 sq. meters.

Sizing Methodology & Factors

The calculator implements standard EPA-recommended adjustments:

  • Base cooling requirement: 20 BTU per square foot of room space (for standard ceilings).
  • Ceiling Height: Spaces with ceilings taller than 8 feet require additional capacity to cool the larger volume of air.
  • Sun exposure: If the room is heavily shaded, reduce capacity by 10%. If the room is very sunny, increase capacity by 10%.
  • Occupants: Standard calculation assumes 2 occupants. If more than 2 people regularly use the room, add 600 BTU for each additional person.
  • Kitchen: If the unit is installed in a kitchen, add 4,000 BTU to account for cooking appliances.